Width
715 cm
(=Outer dimension including metal sheeting)
(+32 cm including rain gutters)
Length
2,305 cm

(=Outer dimension including metal sheeting)

Height
370 cm (side), 475 cm (ridge)
Unobstructed floor space
667 x 2,278 cm ≈ 152 m²
Roofpitch
15˚
Maximum snow load
1.30 kN/m² (EN 1991-1-3)
in combination with 0.65 kN/m² wind load

DIN EN 1991-1-3:2010-12 and DIN EN 1991-1-3/NA:2010-12 compliant

Maximum wind load
0.85 kN/m² (EN 1991-1-4)
in combination with 0.70 kN/m² snow load

DIN EN 1991-1-3:2010-12 and DIN EN 1991-1-3/NA:2010-12 compliant

Overhead door (included)
364 x 305 cm (H x W), color RAL 9002 (grey white), clearance 364 cm, including latch for padlock (not included). Cannot be opened from outside.
The door consists of sandwich panels with a thickness of 4 cm. The outside has a micro-profile, the inside is horizontally profiled. Running rails of galvanized steel. Galvanized door fittings. Steel cables with six-fold safety. Spring package is suitable for a minimum of 30,000 door movements. EPDM seals around and between the panels.
Overhead door (only in side walls)
285 x 274 cm (H x W), color RAL 9002 (grey white), clearance 285 cm, including latch for padlock (not included). Cannot be opened from outside.
The door consists of sandwich panels with a thickness of 4 cm. The outside has a micro-profile, the inside is horizontally profiled. Running rails of galvanized steel. Galvanized door fittings. Steel cables with six-fold safety. Spring package is suitable for a minimum of 30,000 door movements. EPDM seals around and between the panels.
Electric opener overhead door (optional)
220V drive unit with LED lighting + 2x remote control + complete installation set
Man door (1 included)
Opening dimensions 209 x 93 cm, color RAL 9002 (grey white), including door handle with backplate and integrated lock (1 key, prepared for 17mm cilinder). All-steel door with rock wool filling, sheet thickness 0.9 mm, with four-sided EPDM sealing rubbers. Direction of rotation can be executed both left and right.
Door positions
The storage building comes standard with an overhead door and a man door in the front wall. Other door positions are possible, taking into account:
1) An overhead door opening occupies the full width of a truss section in a side wall. The total door construction (including shafts) is therefore wider than a truss section.
2) An overhead door opens by means of rails that hang horizontally in the space, so that the guide rails can interfere with each other with certain door position combinations.

This means that:
– an overhead door in the side wall cannot be placed in the first or last truss section
– there must always be at least 1 truss section between 2 overhead doors
– two overhead doors in the side wall cannot be placed opposite each other
– for an overhead door in the front wall:
an overhead door cannot be placed in the first two sections or the last section of the side wall
– for an overhead door in the front and back walls:
an overhead door cannot be placed in the first two or last two sections of the side wall
– wind bracing may be moved, but not to the first or last section
– man doors may be placed in any section, except those with wind bracing

Metal sheeting
– Roof panel: profiled sandwich panel. Insulant: PIR (NEN-EN14509)
– Wall panel: profiled sandwich panel. Insulant: PIR (NEN-EN14509)

Polyester coating, thickness 25 μm, maintenance free. Innerside wall panels RAL 9002 (grey white).

For the outside of the roof panels you can choose between the colors RAL 9002 (grey white) and 7016 (anthracite grey)
For the outside of the wall panels you can choose between the colors RAL 9006 (white aluminium), 7038 (agate grey) and 7016 (anthracite grey)*

*Colors can slightly differ from reality.

Skylights
10 insulated polycarbonate skylight panels 1100TR3+. Thickness 40 mm. Dimensions light surface 376 x 110 cm per panel.
Steel structure
Galvanized steel S390, c-profile, thickness 1,5 / 2,5 mm, truss distance 2,87 meter.
Gutter system (optional)
Set of steel roof gutters and downspouts in the colors Aluzinc or RAL 7016 (anthracite), width of gutter 125 mm, diameter of downspout 80 mm
Anchoring
For a permanently installed building
Option 1. Concrete foundation
Concrete (strip) foundation to be prepared according to Kroftman drawings (included). Base rail of building is bolted with concrete anchors M12x180/020-035 (included). The concrete surface needs to be perfectly straight to obtain a watertight joint of the walls.

Option 2. Prefab concrete slab elements
Construct a sandbed to the frost line containing a spacious floor of prefab concrete panels (concrete slab elements) of 16 cm minimum. The soil profiles of the storage building need to be fastened with concrete anchors M12x180/020-035 (not included).

This option is economical and fast. The surface must be flat, with a permitted slope of max. 1 cm/m1 in one direction only. A curved surface is not allowed. A slope in the installation surface must be filled out during installation, resulting in additional work.

For a temporarily or semi-permanently installed building
Option 3. Earth anchors (not included)*
Earth anchors 1,200 x 25 mm for anchoring on pavement, asphalt or hard gravel. The installation surface must be straight with a maximum slope of 1cm/m1 limited to one direction. A curved surface is not allowed. A slope in the installation surface must be filled out during installation, resulting in additional work. Base rail holes of ∅30 mm are to be drilled on-site. (adequate holes aw is included).

Installation of your steel building with earth anchors saves time and money and is the perfect solution when only temporily constructions are allowed or needed.

Average assembly time for DIY with 4 persons
5 days

Some parts need to be made to fit on-site.

Shipping weight and dimensions (L x W x H)
6,100 kg, 400 x 120 x 140 cm (4 pallets)
Documentation
Construction drawings, structural calculations in accordance with EUROCODE and assembly manuals are included free of charge.
Warranty
Metal sheeting and gutter system:
10 years descending warranty against rust perforation and discoloration

Steel structure:
10 years descending warranty against rust perforation

Skylights:
10 years descending warranty against breakage

Overhead door and man door:
10 years descending warranty against rust perforation and discoloration, 1 year mechanical warranty. Electric opener: 2 years or 5.000 cycles

Assembly:
6 months warranty on correction installation of the supplied materials if assembled by Kroftman (or its partners).

Options
– Electric opener for overhead door (including 2 remote controls)
– Earth anchors
– Gutter system in the colors Aluzinc or RAL 7016 (anthracite grey)
– Extra man doors (non-matching keys)
– Overhead door in back wall (From H709 )
– Overhead door in side walls 245 x 275 cm (H x B) from H712h and longer if there is no overhead door in the front wall, otherwise from H714h